Ultrasonic Digital Flaw Detectors - RDG 2000 - -2500- 2500S
The new design RDG 2000-2500-2500S digital flaw detectors are equipped with a high bright- ness screen for A-scan presentation and an op- erator interface via dedicated keyboard and video displays set around the special wave- forms panel. With different measurement methods available, special functions, an internal data logger, and complete output ability, the RDG 2000-2500- 2500S detectors are the most versatile of the new generation.
The high protection IP67 allows the use in workshops and construction sites being pro- tected against water and oil. RDG 2000, 2500 and 2500S can be used DAC or TGC and AVG/DGS curves. The DAC curves, which can be drawn on 10 points, can be selected on 3 level (0, -6, -12dB and one custom)with the possibility to read echo height respect to the selected curve. The AVG/DGS curves, for straight probes (e.g. DP25/2, DP25/4 and DP10/4) allow evaluation of the flaw equivalent diameter even when at- tenuation or transfer losses occur. The LCD colour TFT 7” display with adjust- able brightness, can work even in unfavourable light conditions.
Flip monitor function allows the automatic screen rotation depending on the handle opera- tor (hand right/left).
The new RDG 2500S ultrasonic flaw detector can automatically interface with the multi- transducer rotating probe dedicated to specific control of solid axles for railway field. It is configured to load calibration of the transducer selected by the switch on the rotat- ing probe. Each calibration panel recalled is identified by a message show on the display. Amplitude and depth analogical ouputs, video output (S-video) and a USB port are provided to be connected to PC. A optional software program operating under WINDOWS, is disposable to download to PC, calibration panels (100 memories complete of notes), defect (A-scan 1000) and thickness data (10000) stored in the unit (4000 for RDG 2000).
The very easy interaction with the operator, the very low weight (1.6 Kg with battery), the small size and the high battery life (> 14h) identify the RDG as a very versatile and useful tool for the ultrasonic general inspection.
Frequency field: from 0.5 to 15 MHz, Tuning: 0.5÷3, 2.5÷7, 7÷12MHz and 0.5÷15MHz (wide)
Inspection depth: from 0mm to 15m (RDG2500-2500S), from 0mm to 10m - (RDG2000) (O.L. Fe).
Calibrated delay: from 0 mm to 15m - (RDG2500-2500S) from 0mm a 10m - (RDG2000) (O.L. Fe). P .R.F .: Selectable 15 to 5000Hz (RDG2500-2500S), from 15 to 1500Hz (RDG2000). Offset: from 0 to 2.5 msec.
Velocity: from 1000 to 10000 m/s. Pulse voltage: bipolar square wave from 50÷400 +Burst, From 50÷250V without Burst (RDG2000). Gain: 0-110 dB (0÷80 by 0.1, 1, 2, 6 e 10dB steps +, attenuator filter echo÷30dB).
Threshold: 0-50% HS linear with led alarm. Interface rotating probe (Only for RDG 2500S).
MEASUREMENT MODES:
Reflection and through-transmission.
Gate distance and amplitude measurement. Echo - Echo distance.
Trigonometric view of beam path surface, distance and depth of indication, curve surface (CSC only for RDG2500 - 2500S). 2 Gate for measuring of distance and amplitude (independent gate).
Cursor for measuring, distance and amplitude.
Echo start for immersion control (RDG2500 - 2500S).
HARDWARE
Display: LCD Colour TFT, display area 153 x 93 mm (800 x 480 pixels).
USB connector: For PC connection.
Battery charger: 90÷260Vac, 50-60Hz.
Power: rechargeable Li-ion batteries of 14,4V, autonomy up to 14 hours with indication of batteries status.
Recharge time: 4 hours. Weight: 1,6 Kg with battery kit.
Dimensions: 270 x 165 x 65 mm.
Working temperature: from-10°C to +50°C. Storage temperature: from -20°C to +60°C.
Protection: IP67
Internal Function:
DAC curve: up to 10 point stored; displayed 3 curves (0, -6, -12dB) and one custom.
AVG/DGS: based on universal diagram. TGC curve: max. 10 points, dynamic max. 80dB.
Dual sensitivity after the end of the curve.
Echo filter attenuatorn 0 ÷ 30 dB.
Monitor: 2 completely independents gates with alarm, position and width, controllable over full range + gate IF for synchronism gate 1 and 2 (only for RDG2500 -
2500S).
Amplification 0 -100% FSH. Trigger: Polarity positive / negative with audible and visual alarm.
Freezing function.
Echodynamic analysis.
Autocalibration on two echoes.
Storage: 50 calibration and 1000 A-Scan (RDG2000). 100 calibration and 1000 A-Scan (RDG2500).<br /> 100 calibration +50 (for rotating probe) and 1000 A-Scan (RDG2500S).
Data Logger: 10000 data of thickness (RDG2500 - 2500S) - 4000 data (RDG2000).
Possibility to A-Scan storage with AVG/DGS curves.
Possibility of recall setting in automatical and codified mode (with rotating probe RDG2500S).
Unit of measurement: Metric (mm), Inch (in) or time (microsecond).
Help on line: Instant operator guide, with frontal dedi- cated pushbutton .
2 main languages (Italian and English). Output: USB, S-video, ANA analog output for distance and amplitude + contact for alarms.
Connector for interface with rotary switch (RDG 2500S). Conformity declaration according to En12668 part 1.
CE Marking.